Amphenol SGX Sensortech - Air Quality Sensors
784 ResultsPart | Availability | Purchasing | RoHS/Lead | Type | Sensor Type | Measuring Range - Min | Measuring Range - Max | Accuracy | Output Type | Supply Voltage - Min | Supply Voltage - Max | Minimum Operating Temperature | Maximum Operating Temperature | Output Voltage | Mounting Style | Series | Part # Aliases |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr: SGX4410-A2R TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Digital VOC Sensor 2000ppm, sticker, 12-LGA, Reel | 0In Stock | Gas Sensor | 160 PPB | 10000 PPB | 1.7 V | 3.6 V | - 40 C | + 85 C | SMD/SMT | SGX4 | |||||||
0In Stock | Thermal Conductivity | Light Gases (H2, He), CO2, CH4 | 0 % | 100 % | Analog | - 20 C | + 65 C | 3.5 V | Wire | Thermal Conductivity | |||||||
0In Stock | Infrared - Analog | Hydrocarbon | 0 % | 100 % | Analog | 3 V | 5 V | - 20 C | + 55 C | Through Hole | IR1x Series | ||||||
Mfr: PSD4-ETO-200 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PSD4 Series Ethylene Oxide Digital Solid Polymer Sensor CO 200ppm | 0In Stock | Solid Polymer | ETO | 0 PPM | 200 PPM | 5 % | UART | 3.3 VDC | 12 VDC | - 40 C | + 55 C | Through Hole | PSD4 Series | ||||
Mfr: PSD4-HCN-50 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PSD4 Series Hydrogen Cyanide Digital Solid Polymer Sensor 50ppm | 0In Stock | Solid Polymer | HCN | 0 PPM | 50 PPM | 5 % | UART | 3.3 VDC | 12 VDC | - 40 C | + 55 C | Through Hole | PSD4 Series | ||||
0In Stock | Electro-Chemical | O3 | 0 PPM | 5 PPM | Analog | Through Hole | Electro-Chemical | ||||||||||
Mfr: PSD4-H2-5000 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PSD4 Series Hydrogen Digital Solid Polymer Sensor 5000ppm | 0In Stock | Solid Polymer | H2 | 0 PPM | 5000 PPM | 5 % | UART | 3.3 V | 12 V | - 40 C | + 55 C | Through Hole | PSD4 Series | ||||
0In Stock | Integrated Infrared (INIR) | R32 | 100 % | UART and Analog | Through Hole | INIR5 Series | |||||||||||
Mfr: PSD4-SMELL-500 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PSD4 Series SMELL Digital Solid Polymer Sensor 500ppm | 0In Stock | Solid Polymer | Smell | 0 PPM | 500 PPM | 5 % | UART | 3.3 VDC | 12 VDC | - 40 C | + 55 C | Through Hole | PSD4 Series | ||||
Mfr: PS1-H2-20000 TTI: PS1-H2-20000 Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Hydrogen 20Kppm | 0In Stock | Gas Sensor | Hydrogen (H) | - 40 C | + 55 C | Through Hole | PS1 Series | ||||||||||
Mfr: PS4-H2-20000 TTI: PS4-H2-20000 Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS4 Series Solid Polymer Gas Sensor Hydrogen 20Kppm | 0In Stock | Gas Sensor | Hydrogen (H) | PS4 Series | |||||||||||||
Not Available Online | Gas Sensor | Hydrogen (H) | 9 V | 18 V | - 40 C | + 85 C | SGX-BLD1 | ||||||||||
Not Available Online | Gas Sensor | Multi-Gas | 9 V | 18 V | - 40 C | + 85 C | SGX-BLD2 | ||||||||||
Mfr: INIR-RF-R600 TTI: Not Assigned Amphenol SGX Sensortech Availability: Not Available OnlineAir Quality Sensors Int Infrared refrig R600 - 100%LEL | Not Available Online | Gas Sensor | 3.2 V | 5.25 V | - 40 C | + 75 C | Through Hole | INIR Series | |||||||||
Mfr: PID-10.6eV-3B TTI: Not Assigned Amphenol SGX Sensortech Availability: Not Available OnlineAir Quality Sensors | Not Available Online | Gas Sensor | Total Volatile Organic Compound (TVOC) | 3.6 V | 10 V | 0 C | + 40 C | 3.2 V | PCB Mount | PID Series | |||||||
Mfr: PID-10.0eV-100B TTI: Not Assigned Amphenol SGX Sensortech Availability: Not Available OnlineAir Quality Sensors | Not Available Online | Gas Sensor | Total Volatile Organic Compound (TVOC) | 3.6 V | 10 V | - 40 C | + 65 C | 3.2 V | PCB Mount | PID Series | |||||||
Mfr: PS4-CO-100-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: Not Available OnlineAir Quality Sensors | Not Available Online | Carbon Monoxide | Carbon Monoxide | 5 % | Digital | - 40 C | + 55 C | PCB Mount | PS4-Modules | ||||||||
Mfr: PS4-SMELL-500-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: Not Available OnlineAir Quality Sensors | Not Available Online | Gas Sensor | PS4-Modules | ||||||||||||||
Mfr: INIR7-R290-CAN-S1 TTI: Not Assigned Amphenol SGX Sensortech Availability: Not Available OnlineAir Quality Sensors | Not Available Online | Leakage Detection Sensor | R290 (Propane) | 200 PPM | CAN | 4.5 V | 30 V | - 40 C | + 75 C | Board Mount | INIR7 series | ||||||
Mfr: EC4-10-ETO TTI: Not Assigned Amphenol SGX Sensortech Availability: Not Available OnlineAir Quality Sensors 4 series ETO gas sensor 10ppm | Not Available Online | Gas Sensor | 10 PPM | - 20 C | + 50 C | Through Hole | Electro-Chemical | ||||||||||
Mfr: PS1-O2-25PROC TTI: Not Assigned Amphenol SGX Sensortech Availability: Not Available OnlineAir Quality Sensors | Not Available Online | Gas Sensor | PS1 -Modules | ||||||||||||||
Not Available Online | Infrared - Digital | Carbon Dioxide (CO2) | 0 % | 5 % | UART and Analog | 3.2 V | 5 V | - 40 C | + 75 C | Through Hole | INIR Series | ||||||
Not Available Online | Gas Sensor | CH4, Flammable Gas | |||||||||||||||
Mfr: EC4-1-CLO2 TTI: Not Assigned Amphenol SGX Sensortech Availability: Not Available OnlineAir Quality Sensors 4 Series Chlorine Gas Sensor 1ppm | Not Available Online | Electrochemical 4-series | Chlorine Dioxide | 0 PPM | 1 PPM | Analog | - 20 C | + 50 C | Through Hole | Electro-Chemical | |||||||
Mfr: INIR-RF-R1234 TTI: Not Assigned Amphenol SGX Sensortech Availability: Not Available OnlineAir Quality Sensors Integrated Infra Red R1234-100%LEL (EX-d) | Not Available Online | Gas Sensor | 3.2 V | 5.25 V | - 40 C | + 75 C | Through Hole |