Air Quality Sensors
1.747 ResultsPart | Availability | Purchasing | RoHS/Lead | Type | Sensor Type | Measuring Range - Min | Measuring Range - Max | Accuracy | Output Type | Supply Voltage - Min | Supply Voltage - Max | Minimum Operating Temperature | Maximum Operating Temperature | Output Voltage | Mounting Style | Series |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr: PS1-HCHO-100 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Formaldehyde 100ppm | 0In Stock | Solid Polymer 1-series | Formaldehyde | 0 PPM | 100 PPM | Analog | - 20 C | + 55 C | Through Hole | PS1 Series | ||||||
0In Stock | Gas Sensor | Nitrogen Dioxide (NO2) | - 40 C | + 55 C | Through Hole | PS1 Series | ||||||||||
Mfr: PS1-SO2-100 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Sulfur Dioxide 100ppm | 0In Stock | Solid Polymer 1-series | Sulfur Dioxide | 0 PPM | 100 PPM | Analog | - 40 C | + 55 C | Through Hole | PS1 Series | ||||||
Mfr: PS4-CH4S-100 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS4 Series Solid Polymer Gas Sensor Methyl Mercaptan 100ppm | 0In Stock | Solid Polymer 4-series | Methyl Mercaptan | 0 PPM | 100 PPM | Analog | - 40 C | + 55 C | Panel Mount | PS4 Series | ||||||
Mfr: PS4-CL2-50 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS4 Series Solid Polymer Gas Sensor Chlorine 50ppm | 0In Stock | Gas Sensor | Chlorine (Cl2) | - 20 C | + 40 C | Panel Mount | PS4 Series | |||||||||
Mfr: SGX-NH3-500 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors 4 Series Electrochemical Ammonia 500ppm | 0In Stock | Gas Sensor | Ammonia (NH3) | - 30 C | + 55 C | Panel Mount | Electro-Chemical | |||||||||
Mfr: PS1-O3-100-MOD-I2C TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | Ozone | 0 PPM | 100 PPM | I2C | PS1 -Modules | |||||||||
Mfr: PS1-ETO-200-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | Ethylene Oxide | 0 PPM | 200 PPM | UART | PS1 -Modules | |||||||||
Mfr: PS1-CL2-5-MOD-I2C TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | Chlorine | 0 PPM | 5 PPM | I2C | PS1 -Modules | |||||||||
Mfr: PS1-CO-500-MOD-I2C TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | Carbon Monoxide | 0 PPM | 500 PPM | I2C | PS1 -Modules | |||||||||
Mfr: PS1-H2S-10-MOD-I2C TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | Hydrogen Sulfide | 0 PPM | 10 PPM | I2C | PS1 -Modules | |||||||||
Mfr: PS1-HCHO-1-MOD-I2C TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | Formaldehyde | 0 PPM | 1 PPM | I2C | PS1 -Modules | |||||||||
Mfr: PS1-PH3-2000-MOD-I2C TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Module Phosphine 2000ppm - I2C | 0In Stock | Solid Polymer Module 1-series | Phosphine | 0 PPM | 2000 PPM | 5 % | I2C | 3.3 VDC | 5.5 VDC | - 10 C | + 55 C | PS1 -Modules | ||||
Mfr: PID-10.6eV-2K-C TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors 10.6eV - 0-2000ppm detection range, 500ppb resolution - ATEX and IECEx Certified Sensors | 0In Stock | PID | VOC | 0 PPM | 2000 PPM | Analog | Through Hole | PID Series | ||||||||
Mfr: PS-SMART-PH3-100 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Solid Polymer SMART Phosphine gas sensor probe - 4-20mA and Modbus RTU RS485 - 100ppm | 0In Stock | Solid Polymer | PH3 | 0 PPM | 100 PPM | 5 % | Current | - 40 C | + 85 C | Cable | PS-Smart Series | |||||
Mfr: PID-10.6eV-10 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors 10.6eV - 0-10ppm detection range, 1ppb resolution - CE Certified Sensors | 0In Stock | PID | VOC | 0 PPM | 10 PPM | Analog | Through Hole | PID Series | ||||||||
Mfr: 20019846-00 TTI: Not Assigned TE Connectivity Availability: 0In StockAir Quality Sensors Sensor, AD-102, 6mm, High-Resolution | 0In Stock | Gas Sensor | Air Quality | 4.5 VDC | 5.5 VDC | 0 C | + 60 C | 5 V | Screw | |||||||
0In Stock | Refrigerant Leak Detection Sensor | - 40 C | + 105 C | RGD | ||||||||||||
0In Stock | Gas | 5 % | - 40 C | + 105 C | Panel Mount | MGD | ||||||||||
0In Stock | Gas | 5 % | - 40 C | + 105 C | Panel Mount | MGD | ||||||||||
0In Stock | Gas | 5 % | - 40 C | + 105 C | Panel Mount | MGD | ||||||||||
Mfr: SGX-C2H4-10 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors 4 Series Electrochemical Ethylene Sensor 10ppm | 0In Stock | Electrochemical 4-series | Ethylene | 0 PPM | 10 PPM | Analog | - 20 C | + 50 C | Through Hole | Electro-Chemical | ||||||
Mfr: SGX-CLO2-1 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors 4 Series Electrochemical Chlorine Dioxide 1ppm | 0In Stock | Electrochemical 4-series | Chlorine Dioxide | 0 PPM | 1 PPM | Analog | - 20 C | + 50 C | Through Hole | Electro-Chemical | ||||||
0In Stock | Electrochemical 4-series | Hydrogen Sulfide | 0 PPM | 1000 PPM | Analog | - 200 C | + 500 C | Through Hole | Electro-Chemical | |||||||
0In Stock | Solid Polymer 1-series | Chlorine Dioxide | 0 PPM | 100 PPM | Analog | PS1 Series |