Amphenol - Air Quality Sensors
963 ResultsPart | Availability | Purchasing | RoHS/Lead | Type | Sensor Type | Measuring Range - Min | Measuring Range - Max | Accuracy | Output Type | Supply Voltage - Min | Supply Voltage - Max | Minimum Operating Temperature | Maximum Operating Temperature | Output Voltage | Mounting Style | Series |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr: PS-SMART-SiH4-10 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Solid Polymer SMART Silane gas sensor probe - 4-20mA and Modbus RTU RS485 - 10ppm | 0In Stock | Solid Polymer | SiH4 | 0 PPM | 10 PPM | 5 % | Current | - 40 C | + 85 C | Cable | PS-Smart Series | |||||
Mfr: PS-SMART-SMELL-200 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Solid Polymer SMART Smell gas sensor probe - 4-20mA and Modbus RTU RS485 - 200ppm | 0In Stock | Solid Polymer | Smell | 0 PPM | 200 PPM | 5 % | Current | - 40 C | + 85 C | Cable | PS-Smart Series | |||||
Mfr: SGX-4CO-HRH TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors 4 series Electrochemical Carbon Monoxide sensor for High RH environments and fast response/recovery 2000ppm | 0In Stock | Electro-Chemical | CO | 0 PPM | 2000 PPM | Analog | - 40 C | + 50 C | Through Hole | Electro-Chemical | ||||||
Mfr: SGX-H2-5%-LP TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Low Profile Electrochemical Hydrogen sensor 5% | 0In Stock | Electrochemical Low_profile series | Hydrogen | 0 % | 5 % | Analog | Electro-Chemical | |||||||||
Mfr: PS1-CO-100K-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | Carbon Monoxide | 0 PPM | 100000 PPM | UART | PS1 -Modules | |||||||||
Mfr: PID-10.6eV-10K-C TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors 10.6eV - 0-10000ppm detection range, 2ppm resolution - ATEX and IECEx Certified Sensors | 0In Stock | PID | VOC | 0 PPM | 10000 PPM | Analog | Through Hole | PID Series | ||||||||
0In Stock | Electrochemical 4-series | Ethylene Oxide | 0 PPM | 100 PPM | Analog | Electro-Chemical | ||||||||||
0In Stock | Electrochemical 4-series | Germane | 0 PPM | 1 PPM | Analog | Electro-Chemical | ||||||||||
Mfr: SGX4410-A1V TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Digital VOC Sensor 2000ppm, 12-LGA, Tray | 0In Stock | Gas Sensor | 160 PPB | 10000 PPB | 1.7 V | 3.6 V | - 40 C | + 85 C | SMD/SMT | SGX4 | ||||||
0In Stock | Metal Oxide | Nitrogen Dioxide | 50 PPB | 10 PPM | Impedance | 4.9 V | 5.1 V | - 30 C | + 85 C | SMD/SMT | MICS Series | |||||
0In Stock | Metal Oxide | Carbon Monoxide + Nitrogen Dioxide | 50 PPB, 1 PPM | 10 PPM, 1000 PPM | Impedance | 4.9 V | 5.1 V | - 30 C | + 85 C | SMD/SMT | MICS Series | |||||
Mfr: SGX-4NO2-2E TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors 4 Series NO2 Sensor 2 Electrode - 20ppm | 0In Stock | Electrochemical 4-series | Nitrogen Dioxide | 0 PPM | 20 PPM | Analog | - 30 C | + 50 C | Through Hole | Electro-Chemical | ||||||
Mfr: T8100-NSP-GN TTI: Not Assigned Amphenol Advanced Sensors Availability: 0In StockAir Quality Sensors | 0In Stock | Gas Sensor | ||||||||||||||
0In Stock | Gas Sensor | |||||||||||||||
Mfr: PS1-NO2-5-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Module Nitrogen Dioxide 5ppm - UART | 0In Stock | Solid Polymer | NO2 | 0 PPM | 5 PPM | 5 % | UART | - 40 C | + 55 C | Through Hole | PS1 -Modules | |||||
Mfr: PS1-O3-100 TTI: Not Assigned Amphenol SGX Sensortech Availability: Not Available OnlineAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Ozone 100ppm | Not Available Online | Solid Polymer 1-series | Ozone | 0 PPM | 100 PPM | Analog | 3.3 V | 5.5 V | - 40 C | + 55 C | PCB Mount | PS1 Series | ||||
Mfr: PS4-NO2-50 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS4 Series Solid Polymer Gas Sensor Nitrogen Dioxide 50ppm | 0In Stock | Solid Polymer 4-series | Nitrogen Dioxide | 0 PPM | 50 PPM | Analog | - 40 C | + 55 C | Through Hole | PS4 Series | ||||||
Mfr: PS4-VOC-2000 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS4 Series Solid Polymer Gas Sensor VOC 2000ppm | 0In Stock | Solid Polymer 4-series | Volatile Organic Compounds (VOCs) | 0 PPM | 2000 PPM | Analog | - 40 C | + 55 C | PS4 Series | |||||||
0In Stock | Gas Sensor | Electro-Chemical | ||||||||||||||
Mfr: PS1-CO-500-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | Carbon Monoxide | 0 PPM | 500 PPM | 5 % | UART | - 40 C | + 55 C | Through Hole | PS1 -Modules | |||||
Mfr: PS1-NO2-50-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | Nitrogen Dioxide | 0 PPM | 50 PPM | 5 % | UART | - 40 C | + 55 C | Through Hole | PS1 -Modules | |||||
Mfr: PS1-SO2-100-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | Sulfur Dioxide | 0 PPM | 100 PPM | 5 % | UART | - 40 C | + 85 C | PS1 -Modules | ||||||
Mfr: PS1-VOC-2000 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor VOC 2000ppm | 0In Stock | Solid Polymer 1-series | Volatile Organic Compounds (VOCs) | 0 PPM | 2000 PPM | Analog | - 40 C | + 55 C | PS1 Series | |||||||
Mfr: PS4-CO-10000 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS4 Series Solid Polymer Gas Sensor Carbon Monoxide 10Kppm | 0In Stock | Gas Sensor | Carbon Monoxide (CO) | PS4 Series | ||||||||||||
Mfr: PS4-H2S-5000 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS4 Series Solid Polymer Gas Sensor Hydrogen Sulfide 5Kppm | 0In Stock | Solid Polymer 4-series | Hydrogen Sulfide | 0 PPM | 5000 PPM | Analog | - 40 C | + 55 C | PS4 Series |