Amphenol - Air Quality Sensors
963 ResultsPart | Availability | Purchasing | RoHS/Lead | Type | Sensor Type | Measuring Range - Min | Measuring Range - Max | Accuracy | Output Type | Supply Voltage - Min | Supply Voltage - Max | Minimum Operating Temperature | Maximum Operating Temperature | Output Voltage | Series |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr: PS-SMART-C2H4-10 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Solid Polymer SMART Ethylene gas sensor probe - 4-20mA and Modbus RTU RS485 - 10ppm | 0In Stock | Solid Polymer | C2H4 | 0 PPM | 10 PPM | 5 % | Current | - 40 C | + 85 C | PS-Smart Series | |||||
0In Stock | Electrochemical 4-series | Methyl Mercaptan | 0 PPM | 10 PPM | Analog | Electro-Chemical | |||||||||
Mfr: SGX-BR2-5-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Gas Sensor | Electro-Chemical | ||||||||||||
0In Stock | Solid Polymer 4-series | Carbon Monoxide | 0 PPM | 10 PPM | Analog | PS4 Series | |||||||||
0In Stock | Solid Polymer 4-series | Hydrogen | 0 PPM | 50000 PPM | Analog | PS4 Series | |||||||||
0In Stock | MEMS Pellistor | Flammable | 0 % | 5 % | Analog | 1.6 V | 3.2 V | - 20 C | + 60 C | MPEL | |||||
Mfr: PS1-PH3-2000-MOD-I2C TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Module Phosphine 2000ppm - I2C | 0In Stock | Solid Polymer Module 1-series | Phosphine | 0 PPM | 2000 PPM | 5 % | I2C | 3.3 VDC | 5.5 VDC | - 10 C | + 55 C | PS1 -Modules | |||
Mfr: PS1-HCHO-1-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | 0 PPM | 1 PPM | 10 %, 15 % | UART | - 40 C | + 55 C | PS1 -Modules | ||||||
0In Stock | Electrochemical 4-series | Hydrogen Chloride | 0 PPM | 50 PPM | Analog | - 200 C | + 500 C | Electro-Chemical | |||||||
Mfr: SGX4410-A2V TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors Digital VOC Sensor 2000ppm, sticker, 12-LGA, Tray | 0In Stock | Gas Sensor | 160 PPB | 10000 PPB | 1.7 V | 3.6 V | - 40 C | + 85 C | SGX4 | ||||||
Mfr: PS4-VOC-200 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS4 Series Solid Polymer Gas Sensor VOC 200ppm | 0In Stock | Solid Polymer 4-series | Volatile Organic Compounds (VOCs) | 0 PPM | 200 PPM | Analog | - 40 C | + 55 C | PS4 Series | ||||||
Mfr: INIR2-CD5-PC-POS TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Infrared - Digital | Carbon Dioxide (CO2) | 0 % | 5 % | UART and Analog | INIR2 Series | ||||||||
0In Stock | Infrared - Analog | Carbon Dioxide (CO2) | 0 % | 5 % | Analog | 3 V | 5 V | - 20 C | + 55 C | IR3x Series | |||||
0In Stock | Infrared - Analog | Carbon Dioxide (CO2) | 0 % | 5 % | Analog | 5 V | - 20 C | + 60 C | 2.5 V | IR6xx Hazardous Series | |||||
0In Stock | Electrochemical 4-series | Carbon Monoxide + Hydrogen Sulfide | 0 PPM | 500 PPM, 200 PPM | Analog | - 30 C | + 50 C | Electro-Chemical | |||||||
0In Stock | Electrochemical 7-series | Carbon Monoxide | 0 PPM | 1000 PPM | Analog | - 30 C | + 50 C | Electro-Chemical | |||||||
0In Stock | Electrochemical 7-series | Oxygen | 0 % | 25 % | Analog | - 30 C | + 50 C | Electro-Chemical | |||||||
0In Stock | Catalytic | Flammable | Analog | VQ Series | |||||||||||
Mfr: PID-10.6eV-10 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors 10.6eV - 0-10ppm detection range, 1ppb resolution - CE Certified Sensors | 0In Stock | PID | VOC | 0 PPM | 10 PPM | Analog | PID Series | ||||||||
Mfr: PS1-CO-SMOKE-10K TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Carbon Monoxide-SMOKE 10Kppm sensor | 0In Stock | Gas Sensor | Carbon Monoxide (CO) | - 10 C | + 45 C | PS1 Series | |||||||||
Mfr: PS1-ETO-10 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Ethylene Oxide 10ppm | 0In Stock | Solid Polymer 1-series | Ethylene Oxide | 0 PPM | 10 PPM | Analog | - 40 C | + 55 C | PS1 Series | ||||||
Mfr: PS1-HCHO-100 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Formaldehyde 100ppm | 0In Stock | Solid Polymer 1-series | Formaldehyde | 0 PPM | 100 PPM | Analog | - 20 C | + 55 C | PS1 Series | ||||||
Mfr: PS1-IAQ-200-MOD TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors | 0In Stock | Solid Polymer Module 1-series | 0 PPM | 200 PPM | UART | PS1 -Modules | |||||||||
0In Stock | Gas Sensor | Nitrogen Dioxide (NO2) | - 40 C | + 55 C | PS1 Series | ||||||||||
Mfr: PS1-SO2-100 TTI: Not Assigned Amphenol SGX Sensortech Availability: 0In StockAir Quality Sensors PS1 Series Solid Polymer Gas Sensor Sulfur Dioxide 100ppm | 0In Stock | Solid Polymer 1-series | Sulfur Dioxide | 0 PPM | 100 PPM | Analog | - 40 C | + 55 C | PS1 Series |